Generation | Zonda | ||
Tower model 0.8&0.9PF | 15K | 20K | |
CAPACITY(VA/W) | 15kVA/13.5kW | 20kVA/18kW | |
Input | |||
Voltage Range | 208~478Vac | ||
Frequency Range | 45Hz-55Hz @ 50Hz , 54Hz - 66Hz @ 60Hz, Auto Sensing for 50/60Hz UTILITY | ||
Phase | Three Phase + Neutral + Ground | ||
Power Factor | >=0.99 | ||
Generator Input | Support | ||
Output | |||
Voltage | 220Vac/230Vac/ 240Vac could be set by LCD and RS232, USB | ||
Power Factor | 0.8、0.9(optional) | ||
Voltage Regulation | ±1% | ||
Frequency Range | Sychronized Range | 45-55Hz ±0.02Hz@ 50Hz, 54-66Hz ±0.02Hz@60Hz | |
Battery Mode & None Sychronized Range | 50/60Hz±0.02Hz | ||
Current Crest Ratio | 3:1 | ||
Harmonic Distortion | <=2% THD(Linear Load) | ||
<=5% THD(Non-Linear Load) | |||
Output Waveform | Pure Sinewave | ||
Overload Capacity | Line Mode | Load≤110%: last 60min,≤125%: last 10min,≤150%: last 1min ≥150% shut down UPS immediately | |
Battery Mode | Load≤110%: last 10min,≤125%: last 1min,≤150%: last 5S ≥150% shut down UPS immediately | ||
Transfer Time | AC to DC | Zero | |
Inverter to Bypass | Zero | ||
Economic Mode(ECO Mode) | support | ||
Frequency converter Mode(Converter Mode) | support(optional) | ||
Bypass output when UPS off | Support | ||
Efficiency | |||
AC Mode | 91% | ||
Battery Mode | 88% | ||
Battery | |||
BATTERY TYPE | 16/18/20 | ||
Numbers | |||
Protect | cut off voltage can be set(1.75-1.80/cell); boost voltage can be set(2.3-2.35V/cell) | ||
Charging current (A)(max.) | 6 | ||
Charging voltage(VDC) | ±108/121.5/135 can be set from 2.2V to 2.29V per cell, float voltage 2.25V/cell default | ||
Indicators | |||
LCD + LED | Load/Battery/Input/Output/Operating Mode Information | ||
Alarm | |||
Battery Mode | Sounding every 2 seconds | ||
Low Battery | Sounding every second | ||
Overload | Sounding every second | ||
Bypass | Sounding every 2 minutes | ||
Fault | Continuously Sounding | ||
Physical | |||
Dimension(D*W*H)mm | 502*250*616 | ||
Net Weight(kg) | 45 | 45 | |
Standards | |||
Safety | IEC/EN62040-1 | ||
EMC | IEC/EN62040-2 | ||
Environment | |||
Operating temperature | 0-40ºC | ||
Relative Humidity | 0-90%(non-condensing) | ||
Altitude | <1500m. when >1500m, derating | ||
Noise Level | <55dB@ 1Meter | ||
Smart RS-232/USB(Preferential) | External Modbus/SNMP card supported by RS232, Software supports Windows Family,Linus | ||
Intelligent Slot | SNMP (standard or mini) ,Modbus card, Relay card |
Generation | Zonda | ||
Tower model 0.8&0.9PF | 15K | 20K | |
CAPACITY(VA/W) | 15kVA/13.5kW | 20kVA/18kW | |
Input | |||
Voltage Range | 208~478Vac | ||
Frequency Range | 45Hz-55Hz @ 50Hz , 54Hz - 66Hz @ 60Hz, Auto Sensing for 50/60Hz UTILITY | ||
Phase | Three Phase + Neutral + Ground | ||
Power Factor | >=0.99 | ||
Generator Input | Support | ||
Output | |||
Voltage | 220Vac/230Vac/ 240Vac could be set by LCD and RS232, USB | ||
Power Factor | 0.8、0.9(optional) | ||
Voltage Regulation | ±1% | ||
Frequency Range | Sychronized Range | 45-55Hz ±0.02Hz@ 50Hz, 54-66Hz ±0.02Hz@60Hz | |
Battery Mode & None Sychronized Range | 50/60Hz±0.02Hz | ||
Current Crest Ratio | 3:1 | ||
Harmonic Distortion | <=2% THD(Linear Load) | ||
<=5% THD(Non-Linear Load) | |||
Output Waveform | Pure Sinewave | ||
Overload Capacity | Line Mode | Load≤110%: last 60min,≤125%: last 10min,≤150%: last 1min ≥150% shut down UPS immediately | |
Battery Mode | Load≤110%: last 10min,≤125%: last 1min,≤150%: last 5S ≥150% shut down UPS immediately | ||
Transfer Time | AC to DC | Zero | |
Inverter to Bypass | Zero | ||
Economic Mode(ECO Mode) | support | ||
Frequency converter Mode(Converter Mode) | support(optional) | ||
Bypass output when UPS off | Support | ||
Efficiency | |||
AC Mode | 91% | ||
Battery Mode | 88% | ||
Battery | |||
BATTERY TYPE | 16/18/20 | ||
Numbers | |||
Protect | cut off voltage can be set(1.75-1.80/cell); boost voltage can be set(2.3-2.35V/cell) | ||
Charging current (A)(max.) | 6 | ||
Charging voltage(VDC) | ±108/121.5/135 can be set from 2.2V to 2.29V per cell, float voltage 2.25V/cell default | ||
Indicators | |||
LCD + LED | Load/Battery/Input/Output/Operating Mode Information | ||
Alarm | |||
Battery Mode | Sounding every 2 seconds | ||
Low Battery | Sounding every second | ||
Overload | Sounding every second | ||
Bypass | Sounding every 2 minutes | ||
Fault | Continuously Sounding | ||
Physical | |||
Dimension(D*W*H)mm | 502*250*616 | ||
Net Weight(kg) | 45 | 45 | |
Standards | |||
Safety | IEC/EN62040-1 | ||
EMC | IEC/EN62040-2 | ||
Environment | |||
Operating temperature | 0-40ºC | ||
Relative Humidity | 0-90%(non-condensing) | ||
Altitude | <1500m. when >1500m, derating | ||
Noise Level | <55dB@ 1Meter | ||
Smart RS-232/USB(Preferential) | External Modbus/SNMP card supported by RS232, Software supports Windows Family,Linus | ||
Intelligent Slot | SNMP (standard or mini) ,Modbus card, Relay card |